Waterproof cable connector sizing starts with two measurements. The seal fits around the outside of the cable jacket. Inside the connector, each terminal accepts a specified range of conductor sizes. A cable can meet one requirement and miss the other.

A marking such as 3 × 1.5 mm² describes three cores with a nominal conductor cross-section of 1.5 mm² each. It does not tell you the outside diameter of the finished cable. Look for “overall diameter” or “OD,” usually given in millimeters, on the cable datasheet.
Imagine two cables with the same core count and wire size. A thicker jacket on one cable can change which seal fits. Compare each cable’s outside diameter, including its stated tolerance, with the entry range for the exact connector. Then check conductor type, cross-section and pole count against the terminal specification.
Cable A: three cores, 1.5 mm² per core, overall diameter 8.0–8.4 mm. Cable B: the same cores, overall diameter 9.2–9.6 mm. A connector entry specified for 8–9 mm covers the stated diameter of cable A only. These figures illustrate the comparison. Use the actual model datasheet to check the cable entry and terminal ranges.
Submit technical specifications to receive professional drawings and finalized quotes within 24 hours.